EN 12464-1 - Lighting
Indoor Workplace Lighting Standards
Achieving Compliance with EN 12464-1 in Lighting
EN 12464-1 is a European standard that specifies the lighting requirements for indoor workplaces to ensure visual comfort and performance. Compliance with this standard involves several key steps and considerations:
Key Requirements of EN 12464-1
Illuminance Levels (Lux)
Definition: Lux is the unit of measurement for illuminance, indicating the amount of light per square meter.
Requirement: The standard specifies minimum lux levels for different types of workspaces. For example, general office areas typically require at least 500 lux
Unified Glare Rating (UGR)
Definition: UGR measures the discomfort glare caused by lighting fixtures.
Requirement: The standard sets maximum UGR values to ensure visual comfort. For office environments, a UGR of 19 or lower is recommended
Colour Rendering Index (CRI)
Definition: CRI measures how accurately a light source reveals the colours of objects compared to natural light.
Requirement: The standard requires a minimum CRI of 80 for most indoor workspaces to ensure accurate colour representation
Lighting Uniformity
Definition: Uniformity refers to the even distribution of light across a workspace.
Requirement: The standard specifies minimum uniformity ratios to avoid areas of excessive brightness or darkness, which can cause visual discomfort
Daylight Integration
Definition: Incorporating natural light into the lighting design.
Requirement: The standard encourages the use of daylight to reduce energy consumption and enhance occupant well-being
Steps to Achieve Compliance
Assessment and Planning
- Conduct a thorough assessment of the workspace to determine the specific lighting needs based on the tasks performed and the layout of the area.
- Develop a lighting plan that meets the minimum requirements for lux levels, UGR, CRI, and uniformity.
Selection of Lighting Fixtures
- Choose lighting fixtures that meet the specified criteria for illuminance, glare control, and colour rendering.
- Consider fixtures with adjustable settings to allow for flexibility in achieving the desired lighting conditions.
Installation and Adjustment
- Install the lighting fixtures according to the design plan, ensuring proper placement and alignment to achieve uniform lighting distribution.
- Make necessary adjustments to the lighting settings to meet the required lux levels and UGR values.
Performance Verification
- Conduct on-site measurements to verify that the installed lighting meets the specified requirements for illuminance, glare, and colour rendering.
- Use light meters and other tools to measure lux levels, UGR, and CRI in different areas of the workspace
Documentation and Reporting
- Maintain detailed records of the lighting design, installation, and performance verification processes.
- Prepare a compliance report that documents how the lighting system meets the EN 12464-1 requirements.

designLUX offers comprehensive services to help you achieve compliance with EN 12464-1:
Consultation and Assessment
- We provide expert consultation to assess your current lighting setup and identify areas for improvement.
- Our team conducts detailed assessments to determine the specific lighting needs of your workspace.
Customized Lighting Design
- Our lighting designers create customized plans that meet the EN 12464-1 standards, ensuring optimal lighting conditions for your workspace.
- We select high-quality lighting fixtures that meet the required criteria for illuminance, glare control, and colour rendering.
Performance Verification
- We conduct thorough performance verification to ensure that your lighting systems meet all EN 12464-1 requirements.
- Our team provides detailed documentation and reporting to support your compliance efforts.
By partnering with us, you can ensure that your workspace lighting meets the highest standards for visual comfort and performance. Contact us today to learn more about our services and how we can assist you in achieving compliance with EN 12464-1.
Lighting at the highest level. Contact us and we put you in touch with the right person

Datasheets
Detailed specification datasheets available for all products including tender text.

Certification
CE / Declaration of Conformity, Performances and Warranties.

Quality / Sustainability
Quality & Sustainability are at the core of our business.

Photometric Calculation files
Photometric lighting calculation files available for all products.
Vision & Objectives